116 research outputs found

    ā€œI h 8 uā€: Findings from a five-year study of text and e-mail bullying

    Get PDF
    Copyright @ 2010 British Educational Research Association. The final version of this article is available at the link below.This study charts reports of nasty or threatening text and e-mail messages received by students in academic years 7 and 8 (11-13 years of age) attending 13 secondary schools in the North of England between 2002-2006. Annual surveys were undertaken on behalf of the local education authority (LEA) to monitor bullying. Results indicated that, over five years, the number of pupils receiving one or more nasty or threatening text messages or e-mails increased significantly, particularly among girls. However, receipt of frequent nasty or threatening text and e-mail messages remained relatively stable. For boys, being a victim of direct-physical bullying was associated with receiving nasty or threatening text and e-mail messages; for girls it was being unpopular among peers. Boys received more hate-related messages and girls were primarily the victims of name-calling, Findings are discussed with respect to theoretical and policy developments, and recommendations for future research are offered

    "A calorie is a calorie" violates the second law of thermodynamics

    Get PDF
    The principle of "a calorie is a calorie," that weight change in hypocaloric diets is independent of macronutrient composition, is widely held in the popular and technical literature, and is frequently justified by appeal to the laws of thermodynamics. We review here some aspects of thermodynamics that bear on weight loss and the effect of macronutrient composition. The focus is the so-called metabolic advantage in low-carbohydrate diets ā€“ greater weight loss compared to isocaloric diets of different composition. Two laws of thermodynamics are relevant to the systems considered in nutrition and, whereas the first law is a conservation (of energy) law, the second is a dissipation law: something (negative entropy) is lost and therefore balance is not to be expected in diet interventions. Here, we propose that a misunderstanding of the second law accounts for the controversy about the role of macronutrient effect on weight loss and we review some aspects of elementary thermodynamics. We use data in the literature to show that thermogenesis is sufficient to predict metabolic advantage. Whereas homeostasis ensures balance under many conditions, as a general principle, "a calorie is a calorie" violates the second law of thermodynamics

    Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study

    Get PDF
    To assess whether absolute mass scores are comparable or differ between identical 64-slice MDCT scanners of the same manufacturer and to compare absolute mass scores to the physical mass and between scan modes using a calcified phantom. A non-moving anthropomorphic phantom with nine calcifications of three sizes and three densities was scanned 30 times on three 64-slice MDCT scanners of manufacturer A and on three 64-slice MDCT scanners of manufacturer B in both sequential and spiral scan mode. The mean mass scores and mass score variabilities of seven calcifications were determined for all scanners; two non-detectable calcifications were omitted. It was analyzed whether identical scanners yielded similar or significantly different mass scores. Furthermore mass scores were compared to the physical mass and mass scores were compared between scan modes. The mass score calibration factor was determined for all scanners. Mass scores obtained on identical scanners were similar for almost all calcifications. Overall, mass score differences between the scanners were small ranging from 1.5 to 3.4% for the total mass scores, and most differences between scanners were observed for high density calcifications. Mass scores were significantly different from the physical mass for almost all calcifications and all scanners. In sequential mode the total physical mass (167.8Ā mg) was significantly overestimated (+2.3%) for 4 out of 6 scanners. In spiral mode a significant overestimation (+2.5%) was found for system B and a significant underestimation (āˆ’1.8%) for two scanners of system A. Mass scores were dependent on the scan mode, for manufacturer A scores were higher in sequential mode and for manufacturer B in spiral mode. For system A using spiral scan mode no differences were found between identical scanners, whereas a few differences were found using sequential mode. For system B the scan mode did not affect the number of different mass scores between identical scanners. Mass scores obtained in the same scan mode are comparable between identical 64-slice CT scanners and identical 64-slice CT scanners on different sites can be used in follow-up studies. Furthermore, for all systems significant differences were found between mass scores and the physical calcium mass; however, the differences were relatively small and consistent

    Inter-scan reproducibility of coronary calcium measurement using Multi Detector-Row Computed Tomography (MDCT)

    Get PDF
    Purpose: To assess inter-scan reproducibility of coronary calcium measurements obtained from Multi Detector-Row CT (MDCT) images and to evaluate whether this reproducibility is affected by different measurement protocols, slice thickness, cardiovascular risk factors and/or technical variables. Design: Cross-sectional study with repeated measurements. Materials and methods: The study population comprised 76 healthy women. Coronary calcium was assessed in these women twice in one session using 16-MDCT (Philips Mx 8000 IDT 16). Images were reconstructed with 1.5 mm slice thickness and 3.0 mm slice thickness. The 76 repeated scans were scored. The Agatston score, a volume measurement and a mass measurement were assessed. Reproducibility was determined by estimation of mean, absolute, relative difference, the weighted kappa value for agreement and the Intra-class correlation coefficient (ICCC). Results: Fifty-five participants (72.4%) had a coronary calcification of more than zero in Agatston (1.5 mm slice thickness). The reproducibility of coronary calcium measurements between scans in terms of ranking was excellent with Intra-class correlation coefficients of >0.98, and kappa values above 0.80. The absolute difference in calcium score between scans increased with increasing calcium levels, indicating that measurement error increases with increasing calcium levels. However, no relation was found between the mean difference in scores and calcium levels, indicating that the increase in measurement error is likely to result in random misclassification in calcium score. Reproducibility results were similar for 1.5 mm slices and for 3.0 mm slices, and equal for Agatston, volume and mass measurements. Conclusion: Inter-scan reproducibilility of measurement of coronary calcium using images from MDCT is excellent, irrespective of slice thickness and type of calcium parameter

    Is there a role for CT coronary angiography in patients with symptomatic angina? Effect of coronary calcium score on identification of stenosis

    Get PDF
    Present guidelines discourage the use of CT coronary angiography (CTCA) in symptomatic angina patients. We examined the relation between coronary calcium score (CS) and the performance of CTCA in patients with stable and unstable angina in order to understand under which conditions CTCA might be a gate-keeper to conventional coronary angiography (CCA) in such patients. We included 360 patients between 50 and 70Ā years old with stable and unstable angina who were clinically referred for CCA irrespective of CS. Patients received CS and CCTA on 64-slice scanners in a multicenter cross-sectional trial. The institutional review board approved the study. Diagnostic performance of CTCA to detect or rule out significant coronary artery disease was calculated on a per patient level in pre-defined CS categories. The prevalence of significant coronary artery disease strongly increased with CS. Negative CTCA were associated with a negative likelihood ratio of <0.1 independent of CS. Positive CTCA was associated with a high positive likelihood ratio of 9.4 if CS was <10. However, for higher CS the positive likelihood ratio never exceeded 3.0 and for CS >400 it decreased to 1.3. In the 62 (17%) patients with CS <10, CTCA reliably identified the 42 (68%) of these patients without significant CAD, at no false negative CTCA scans. In symptomatic angina patients, a negative CTCA reliably excludes significant CAD but the additional value of CTCA decreases sharply with CS >10 and especially with CS >400. In patients with CS <10, CTCA provides excellent diagnostic performance

    Incremental value of the CT coronary calcium score for the prediction of coronary artery disease

    Get PDF
    Objectives:: To validate published prediction models for the presence of obstructive coronary artery disease (CAD) in patients with new onset stable typical or atypical angina pectoris and to assess the incremental value of the CT coronary calcium score (CTCS). Methods:: We searched the literature for clinical prediction rules for the diagnosis of obstructive CAD, defined asā‰„50% stenosis in at least one vessel on conventional coronary angiography. Significant variables were re-analysed in our dataset of 254 patients with logistic regression. CTCS was subsequently included in the models. The area under the receiver operating characteristic curve (AUC) was calculated to assess diagnostic performance. Results:: Re-analysing the variables used by Diamond & Forrester yielded an AUC of 0.798, which increased to 0.890 by adding CTCS. For Pryor, Morise 1994, Morise 1997 and Shaw the AUC increased from 0.838 to 0.901, 0.831 to 0.899, 0.840 to 0.898 and 0.833 to 0.899. CTCS significantly improved model performance in each model. Conclusions:: Validation demonstrated good diagnostic performance across all models. CTCS improves the prediction of the presence of obstructive CAD, independent of clinical predictors, and should be considered in its diagnostic work-up. Ā© 2010 The Author(s)

    Small coronary calcifications are not detectable by 64-slice contrast enhanced computed tomography

    Get PDF
    Recently, small calcifications have been associated with unstable plaques. Plaque calcifications are both in intravascular ultrasound (IVUS) and multi-slice computed tomography (MSCT) easily recognized. However, smaller calcifications might be missed on MSCT due to its lower resolution. Because it is unknown to which extent calcifications can be detected with MSCT, we compared calcification detection on contrast enhanced MSCT with IVUS. The coronary arteries of patients with myocardial infarction or unstable angina were imaged by 64-slice MSCT angiography and IVUS. The IVUS and MSCT images were registered and the arteries were inspected on the presence of calcifications on both modalities independently. We measured the length and the maximum circumferential angle of each calcification on IVUS. In 31 arteries, we found 99 calcifications on IVUS, of which only 47 were also detected on MSCT. The calcifications missed on MSCT (nĀ =Ā 52) were significantly smaller in angle (27Ā°Ā Ā±Ā 16Ā° vs. 59Ā°Ā Ā±Ā 31Ā°) and length (1.4Ā Ā±Ā 0.8 vs. 3.7Ā Ā±Ā 2.2Ā mm) than those detected on MSCT. Calcifications could only be detected reliably on MSCT if they were larger than 2.1Ā mm in length or 36Ā° in angle. Half of the calcifications seen on the IVUS images cannot be detected on contrast enhanced 64-slice MSCT angiography images because of their size. The limited resolution of MSCT is the main reason for missing small calcifications

    Predictive value of coronary calcifications for future cardiac events in asymptomatic patients with diabetes mellitus: A prospective study in 716 patients over 8 years

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To establish an efficient prophylaxis of coronary artery disease reliable risk stratification is crucial, especially in the high risk population of patients suffering from diabetes mellitus. This prospective study determined the predictive value of coronary calcifications for future cardiovascular events in asymptomatic patients with diabetes mellitus.</p> <p>Methods</p> <p>We included 716 patients suffering from diabetes mellitus (430 men, 286 women, age 55.2 Ā± 15.2 years) in this study. On study entry all patients were asymptomatic and had no history of coronary artery disease. In addition, all patients showed no signs of coronary artery disease in ECG, stress ECG or echocardiography. Coronary calcifications were determined with the Imatron C 150 XP electron beam computed tomograph. For quantification of coronary calcifications we calculated the Agatston score. After a mean observation period of 8.1 Ā± 1.1 years patients were contacted and the event rate of cardiac death (CD) and myocardial infarction (MI) was determined.</p> <p>Results</p> <p>During the observation period 40 patients suffered from MI, 36 patients died from acute CD. The initial Agatston score in patients that suffered from MI or died from CD (475 Ā± 208) was significantly higher compared to those without cardiac events (236 Ā± 199, p < 0.01). An Agatston score above 400 was associated with a significantly higher annualised event rate for cardiovascular events (5.6% versus 0.7%, p < 0.01). No cardiac events were observed in patients with exclusion of coronary calcifications. Compared to the Framingham risk score and the UKPDS score the Agatston score showed a significantly higher diagnostic accuracy in the prediction of MI with an area under the ROC curve of 0.77 versus 0.68, and 0.71, respectively, p < 0.01.</p> <p>Conclusion</p> <p>By determination of coronary calcifications patients at risk for future MI and CD could be identified within an asymptomatic high risk group of patients suffering from diabetes mellitus. On the other hand future events could be excluded in patients without coronary calcifications.</p
    • ā€¦
    corecore